DC/DC Railway Converter
TEP 200WIRCMF Series, 200 Watt
•
Chassis mount with screw terminal
block
•
Including EMI filter to meet EN 55032,
class A
•
Ultra wide 4:1 input voltage ranges
9–36, 18–75, 43–160 VDC
•
EN 50155 approval for railway
applications
•
•
•
•
•
•
Very high efficiency up to 91%
No minimum load
UL 62368-1 IEC 62368-1
Soft start
Under voltage lock-out circuit
Adjustable output voltage +10 / -20%
Sense line
The TEP 200WIRCMF Series is a family of isolated high performance DC/DC
converter modules with ultra-wide 4:1 input voltage ranges. They come in
chassis mount version with screw terminal block and with integrated EMI input
filter to meet EN 55032 class A. A very high efficiency allows full power operation at 25°C with only 100 LFM air flow cooling and operation at 60°C with only
40% power derating. The very wide input voltage range and reverse input voltage protection make these converters interesting solution for battery operated
systems. Typical applications are in telecom/datacom, industry control and railway systems for onboard power distribution.
Models
Order Code
Input Voltage
Output Voltage
Output Current
Efficiency
Range
nom. (adjustable)
max.
typ.
TEP 200-2412WIRCMF
12 VDC (9.6 - 13.2 VDC)
15'000 mA
89 %
TEP 200-2413WIRCMF
15 VDC (12.0 - 16.5 VDC)
12'000 mA
90 %
24 VDC (19.2 - 26.4 VDC)
7'500 mA
90 %
28 VDC (22.4 - 30.8 VDC)
6'500 mA
90 %
TEP 200-2415WIRCMF
TEP 200-2416WIRCMF
9 - 36 VDC
(24 VDC nom.)
TEP 200-2418WIRCMF
48 VDC (38.4 - 52.8 VDC)
3'700 mA
89 %
TEP 200-4812WIRCMF
12 VDC (9.6 - 13.2 VDC)
18'000 mA
90 %
15 VDC (12.0 - 16.5 VDC)
14'000 mA
91 %
24 VDC (19.2 - 26.4 VDC)
9'000 mA
90 %
28 VDC (22.4 - 30.8 VDC)
7'500 mA
91 %
TEP 200-4813WIRCMF
TEP 200-4815WIRCMF
TEP 200-4816WIRCMF
18 - 75 VDC
(48 VDC nom.)
TEP 200-4818WIRCMF
48 VDC (38.4 - 52.8 VDC)
4'500 mA
90 %
TEP 200-7212WIRCMF
12 VDC (9.6 - 13.2 VDC)
20'000 mA
89 %
15 VDC (12.0 - 16.5 VDC)
16'000 mA
90 %
24 VDC (19.2 - 26.4 VDC)
10'000 mA
89 %
28 VDC (22.4 - 30.8 VDC)
8'500 mA
90 %
48 VDC (38.4 - 52.8 VDC)
5'000 mA
89 %
TEP 200-7213WIRCMF
TEP 200-7215WIRCMF
TEP 200-7216WIRCMF
TEP 200-7218WIRCMF
www.tracopower.com
43 - 160 VDC
(110 VDC nom.)
August 31, 2023
Page 1 / 5
TEP 200WIRCMF Series, 200 Watt
Options
TEP-MK1
- Optional DIN-Rail Mounting Kit: www.tracopower.com/products/tep-mk1.pdf
- Optional model with 3.3 VDC / 50'000 mA Output and 9 - 36 VDC Input
- Optional model with 5 VDC / 36'000 mA Output and 9 - 36 VDC Input
- Optional model with 3.3 VDC / 50'000 mA Output and 18 - 75 VDC Input
- Optional model with 5 VDC / 40'000 mA Output and 18 - 75 VDC Input
on demand
- Optional model with 53 VDC / 3'800 mA Output and 33 - 75 VDC Input
(backorder with MOQ
non stocking item) - Optional model with 3.3 VDC / 57'000 mA Output and 43 - 160 VDC Input
- Optional model with 5 VDC / 44'000 mA Output and 43 - 160 VDC Input
- Optional models with 2:1 Input
- Chassis mount models w/o filter: www.tracopower.com/products/tep200wircm.pdf
- Optional models with inverse Remote On/Off function (passive = off)
Input Specifications
Input Current
- At no load
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
35 mA typ.
20 mA typ.
10 mA typ.
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
185 VDC max. (1 s max.)
7.3 VDC min. / 7.7 VDC typ. / 8.1 VDC max.
15.5 VDC min. / 16 VDC typ. / 16.3 VDC max.
33 VDC min. / 34.5 VDC typ. / 36 VDC max.
32'000 mA (fast acting)
20'000 mA (fast acting)
10'000 mA (fast acting)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Output Specifications
Output Voltage Adjustment
Voltage Set Accuracy
Regulation
Ripple and Noise
(20 MHz Bandwidth)
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
–20% to +10% (By external trim resistor)
See application note: www.tracopower.com/overview/tep200wircmf
Output power must not exceed rated power!
±1% max.
0.1% max.
0.1% max.
3.3 Vout models: 75 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
5 Vout models: 75 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
12 Vout models: 100 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
15 Vout models: 100 mVp-p max. (w/ 1 µF X7R || 25 µF poscap)
24 Vout models: 200 mVp-p max. (w/ 4.7 µF X7R)
28 Vout models: 200 mVp-p max. (w/ 4.7 µF X7R)
48 Vout models: 300 mVp-p max. (w/ 2.2 µF X7R)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
August 31, 2023
Page 2 / 5
TEP 200WIRCMF Series, 200 Watt
Capacitive Load
- 24 Vin input
- 48 Vin input
- 110 Vin input
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
28 Vout models:
48 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
28 Vout models:
48 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
28 Vout models:
48 Vout models:
Minimum Load
Temperature Coefficient
Hold-up Time
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Time
151'000 µF max.
72'000 µF max.
12'500 µF max.
8'000 µF max.
3'100 µF max.
2'300 µF max.
770 µF max.
151'000 µF max.
80'000 µF max.
15'000 µF max.
9'300 µF max.
3'700 µF max.
2'600 µF max.
930 µF max.
172'000 µF max.
88'000 µF max.
16'600 µF max.
10'600 µF max.
4'100 µF max.
3'000 µF max.
1'000 µF max.
Not required
±0.02 %/K max.
10 ms min. (acc. to EN 50155 Class S2, see
application note for ext. capacitor calculation:
www.tracopower.com/info/holdup_en50155.pdf)
75 ms typ.
Continuous, Automatic recovery
120 - 150% of Iout max.
115 - 130% of Vout nom.
200 µs typ. / 250 µs max. (25% Load Step)
Safety Specifications
Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
EN 50155
- IT / Multimedia Equipment
- Railway Applications
- Certification Documents
www.tracopower.com/overview/tep200wircmf
Pollution Degree
Over Voltage Category
PD 2
OVC II
EMC Specifications
EMI Emissions
EN 55011 class A (internal filter)
EN 55032 class A (internal filter)
EN 55011 class A (internal filter)
EN 55032 class A (internal filter)
- Conducted Emissions
- Radiated Emissions
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
August 31, 2023
Page 3 / 5
TEP 200WIRCMF Series, 200 Watt
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 50155 (Railway Applications)
EN 50121-3-2 (EMC for Rolling Stock)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 20 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
24 & 48 Vin models: 2 x KY 220 µF
110 Vin models: 2 x KXJ 150 µF
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Over Temperature
Protection Switch Off
- Protection Mode
- Measurement Point
95% max. (non condensing)
–40°C to +75°C
+115°C max.
–40°C to +105°C
Depending on model
Cooling System
Sense Function
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Working Voltage (rated)
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Environment
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Mechanical Shock
- Thermal Shock
Housing Material
See application note: www.tracopower.com/overview/tep200wircmf
120°C typ. (Automatic recovery at 105°C typ.)
Base-Plate
Natural convection (20 LFM)
10% max. of Vout nom.
(Sense line to be connected to the output either
at the module or at the load under regard of
polarity.)
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
3 mA typ.
-0.5 to 1.0 mA
(Optional models with inverse Remote On/Off
function (passive = off))
2'000 m max. (for reinforced insulation)
5'000 m max. (for functional insulation))
225 - 275 kHz (PWM)
250 kHz typ. (PWM)
Reinforced Insulation
145 VAC (3.3 and 5 Vout models)
185 VAC (48 and 53 Vout models)
172 VAC (other output models)
3'000 VAC
1'500 VAC
1'500 VAC
1'000 MΩ min.
2'500 pF max.
300'000 h (MIL-HDBK-217F, ground benign)
MIL-STD-810F
EN 61373
MIL-STD-810F
EN 61373
MIL-STD-810F
EN 50155
Alu base-plate w. metal case (24 and 48 Vin
models)
Alu base-plate w. plastic case (110 Vin models)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
August 31, 2023
Page 4 / 5
TEP 200WIRCMF Series, 200 Watt
Base Material
Non-conductive FR4 (UL 94 V-0 rated) (24 and
48 Vin models only)
Silicone (UL 94 V-0 rated)
Metal Case (24 and 48 Vin models)
Plastic Case (110 Vin models)
Chassis Mount
Screw Terminal
287 g
Potting Material
Housing Type
Mounting Type
Connection Type
Weight
Thermal Impedance
- Case to Ambient
Environmental Compliance - REACH Declaration
6.1 K/W typ.
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
- RoHS Declaration
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
814f10c5-0fbd-4350-bd50-90d0539e5374
- SCIP Reference Number
- Flammability (EN 45545-2)
www.tracopower.com/info/en45545-declaration.pdf
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tep200wircmf
Outline Dimensions
85.0 (3.35)
3.5
78.0 (3.071)
(0.14)
Pinout
11.0
(0.14)
3.5
40.5 (1.59) max.
(0.43)
Pin
9
TOP VIEW
6
54.0 (2.126)
7
50.80 (2.0)
screw 1
8
3
2
screw 2
5
61.0 (2.4)
4
(Ø0.17)
4 x Ø4.2
1
1
Through hole
40.6 (1.6)
22.2 (0.89)
Dimensions in mm (inch)
Tolerances x.x ±0.5 (x.xx ±0.02)
x.xx ±0.25 (x.xxx ±0.01)
Mounting hole pitch tolerances ±0.25 (±0.01)
Single
in (GND)
2
Case
3
Remote On/Off
4
+Vin (Vcc)
5
out
6
ense
7
Trim
8
+Sense
9
+Vout
Screw 2:
Type M5
Head diameter 8.9 (0.350)
Rated current: 65 A
The screw 1 locked torque: max. 5.2 kgfcm / 0.51 Nm
The screw 2 locked torque: max. 16.5 kgfcm / 1.65 Nm
Mounting screw locked torque: max. 11.2 kgfcm / 1.10 Nm
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. August 31, 2023